Automotive

AASHTO M294 PDF

Pipe shall be joined with the ADS N ST IB (bell-and-spigot) joint meeting AASHTO M, AASHTO M, or ASTM F The joint shall be soil-tight and . AASHTO M Standard Specification for Corrugated Polyethylene Pipe, to mm ( to in.) Diameter. standard by American Association of. Corrugated Polyethylene Pipe, to mm Diameter. Scope. This specification covers the requirements and strategies of checks for.

Author: Yozshuzahn Kazrazahn
Country: Turkmenistan
Language: English (Spanish)
Genre: Career
Published (Last): 13 October 2006
Pages: 439
PDF File Size: 17.70 Mb
ePub File Size: 17.78 Mb
ISBN: 199-9-42337-349-3
Downloads: 66128
Price: Free* [*Free Regsitration Required]
Uploader: Digrel

The height of aaehto shall be 3. Below is the uncorrected machine-read text of this chapter, intended to provide our own search engines and external engines with highly rich, chapter-representative searchable text of each book. Perforations shall be uniformly spaced along the length and circumference of the pipe. Type of pipe Section 4. Lay the assembly or joint on a flat surface and verify that it will accommodate straight-line flow.

Rounding mm294 to the nearest integer, the minimum average failure time for 5 specimens shall not be less than axshto hours, and no single specimen shall fail in less than 4 hours. For Type CP and SP pipe, the perforations shall asahto located in the external valleys with perforations in each row for each corrugation.

Inspect for damage while at the specified deflection and after load removal. The perforations shall be cleanly cut so as not to restrict the inflow of water. Example illustration of the corrugation height, hp Figure 3: If carbon black concentrate is present in the sampled material, the carbon black concentrate shall be removed prior to further sample preparation.

Titles of the personnel responsible for production quality at the plant s ; X1. The design of the fittings shall be such that when connected with the pipe, the axis of the assembly will be level and true when tested in accordance with Section 9. Make all measurements on the pipe while it is stress-free and at rest on a flat surface in a straight line.

  BREAKING THE VICIOUS CYCLE ELAINE GOTTSCHALL PDF

The following precautionary caveat pertains only to the test method portion, Section 9. These measurements may be taken at ambient temperature.

Figure 2 shows an illustration of the corrugation height, and Figure 3 shows measurement of the inside and outside diameters. Quality control test reports shall include the lot identification. The dry-blended sample shall be fully homogenized by melt blending via a twin screw lab extruder or other melt homogenization technique that has been verified to provide similar levels of homogenization prior to testing for physical properties. An annual update may be required. Field Performance aashyo Corrugated Pipe Manufactured with Recycled Polyethylene Content explores the use of corrugated high density polyethylene HDPE pipe manufactured with recycled content and proposes guidelines for manufacturing these pipes to ensure they meet the service life m249 for the given application.

Aasyto B shall be used, with a mass of 4. An abbreviated procedure is shown below. Group 2 June 1. An example calculation is shown in Appendix X2.

The manufacturer shall ,294 each resin or resin blend lot for full cell class and NCLS, unless a regular quality assurance program is in place to correlate cell class results to density and melt index.

Not a MyNAP member yet?

AASHTO HDPE Pipe

The ends of the pipe shall be cut squarely and cleanly so as not to adversely affect joining or connecting. Use a flat plate specimen holder. When blends of virgin resins are used for pipe manufacture, the final blended resin aaashto meet the requirements of the standard. Calculate the Popelar time and stress multiplication factors to shift the failure times from the elevated temperature test condition to the aasto condition: For Type D pipe, delamination is a separation of the liner and outer wall as evidenced by a visible gap extending completely between the internal supports and liner or outer wall at any point around the circumference of the pipe.

The distance between the centerlines of the rows shall not be less than 25 mm 1 in. The physical location of the plant s ; X1. Based on feedback from you, our users, we’ve made some improvements that make it easier than ever to read thousands of publications on our website.

  KMB RICHTLINIE 2010 PDF

ADS’ LU 2 lb. Split couplings shall engage at least two full corrugations on each pipe section.

Corrugated Polyethylene Pipe AASHTO M —

This appendix should serve as a guide for both the manufacturer and the user. If pipe is made from a non-PPI certified resin or non-PPI certified blend of component resins, the pipe manufacturer should have a resin testing program in place that includes the testing of each component resin and resin blend lot for density and melt index and have the means of conducting in-house or contract lab the remaining cell class and NCLS testing as specified in this standard.

Product Information ADS Dual Wall N drainage pipe, available with multiple joining systems, provides corrugated-pipe strength and smooth interior wall hydraulics for increased flow capacity, in a lifetime package. The plant approval process requires the manufacturer to submit an annual update to the specifying agency. Corrugations shall be annular. The rate of loading shall be the same as in Section 9. Successful performance of this product depends upon proper type of bedding and backfill, and care in installation.

Corrugated PE pipe is intended for surface and subsurface drainage applications where soil provides support to its flexible walls.

The buckling deflection limit shall be determined by the following equation: To search the entire text of this book, type in your search term here and press Enter. To ensure adequate resistance to SCG propagation, NCLS testing shall be conducted on specimens taken either directly from the finished pipe liner or from ground-up pieces of pipe that have been compression-molded into a plaque.

The blended sample shall not contain carbon aasyto concentrate.